Advanced Keyless Entry System Does Not Operate: Procedure
- DETERMINE IF MALFUNCTION CAUSE IS DOOR LOCK
- Refer to "door lock does not operate" symptom troubleshooting and perform the inspection.
Refer to DOOR LOCK DOES NOT OPERATE
- Is the smart key system operating normally?
Result
Result Yes No
Result: 2
Yes
TROUBLESHOOTING COMPLETED. (EXPLAIN THE CONTENTS OF THE SERVICING TO THE CUSTOMER.)
Result: 1
No
See step 2
- Refer to "door lock does not operate" symptom troubleshooting and perform the inspection.
- VERIFY IF MALFUNCTION CAUSE IS OPERATION OTHER THAN OPERATION PERMISSION CONDITION
- Verify the advanced keyless operation by operating each entry lock and unlock switch and the trunk lid opener switch with all the following conditions met.
- All doors and trunk closed
- Ignition switched off
- Door control transmitter is within reception area
(80 cm radius from driver's door, front passenger's door, and trunk)
- Is the smart key system operating normally?
Result
Result Yes No
Result: 2
Yes
SYSTEM IS NORMAL. (EXPLAIN TO CUSTOMER ABOUT OPERATION RANGE OF SMART KEY SYSTEM)
Result: 1
No
See step 3
- Verify the advanced keyless operation by operating each entry lock and unlock switch and the trunk lid opener switch with all the following conditions met.
- VERIFY IF MALFUNCTION CAUSE IS EXTRINSIC NOISE
- Ask the customer malfunction condition.
- Does the malfunction occur at the specified place where extrinsic noise is received such as a TV tower, electric power station, or a broadcast station?
Result
Result Yes No
Result: 2
Yes
SYSTEM IS NORMAL. (EXPLAIN THE CUSTOMER THAT OPERATION CANNOT BE PERFORMED CAUSED BY EXTRINSIC NOISE.)
Result: 1
No
See step 4
- VERIFY MALFUNCTION SYMPTOM
Result: 2
Yes
See step 7
Result: 1
No
See step 5
- DETERMINE IF MALFUNCTION CAUSE IS TRUNK LID OPENER SWITCH
- Measure the voltage at main body ECU terminal E1-10.
- Is the voltage normal?
Specification
- Trunk lid opener switch pressed: 1.0 V or less Except above: 4.5 V
Result
Result Yes No
Result: 2
Yes
See step 12
Result: 1
No
See step 6
- INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN MAIN BODY ECU AND TRUNK LID OPENER SWITCH
- Disconnect the negative battery cable.
Refer to INSTALLATION
- Disconnect the main body ECU and trunk lid opener switch connector
- Inspect for continuity between the following terminals (vehicle wiring harness).
- Trunk lid opener switch terminal E34-3 and main body ECU terminal E1-10
- Is there continuity?
Result
Result Yes No
Result: 1
Yes
See step 18
Result: 2
No
See step 19
- Disconnect the negative battery cable.
- VERIFY MALFUNCTION SYMPTOM
- Connect the negative battery cable.
Refer to INSTALLATION
- Verify the lock/unlock operation for all doors and trunk using the entry lock and unlock switch operation.
- Is door locked/unlocked?
Result
Result Yes No
Result: 2
Yes
See step 12
Result: 1
No
See step 8
- Connect the negative battery cable.
- INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN ENGINE STOP AND START ECU AND DOOR LOCK LINK SWITCH (DRIVER SIDE)
- Disconnect the negative battery cable.
Refer to INSTALLATION
- Disconnect the engine stop and start ECU unit and the front door lock (driver's side) connector.
- Inspect for continuity between the following terminals (vehicle wiring harness).
- Engine stop and start ECU terminal D6-24 and front door lock link switch terminal F18-8
- Is there continuity?
Result
Result Yes No
Result: 2
No
See step 17
Result: 1
Yes
See step 9
- Disconnect the negative battery cable.
- INSPECT IF MALFUNCTION CAUSE IS SHORT TO GROUND IN WIRING HARNESS BETWEEN ENGINE STOP AND START ECU AND DOOR LOCK LINK SWITCH (DRIVER-SIDE)
- Verify that the engine stop and start ECU connector is disconnected.
- Inspect for continuity between the following wiring harness terminals (vehicle wiring harness side) and body ground.
- Engine stop and start ECU terminal D6-24 and ground
- Is there continuity?
Result
Result Yes No
Result: 2
No
See step 16
Result: 1
Yes
See step 10
- INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN ENGINE STOP AND START ECU AND GROUND
- Verify that the engine stop and start ECU connector is disconnected.
- Inspect for continuity between the following terminals (vehicle wiring harness).
- Engine stop and start ECU terminal D6-32 and ground
- Engine stop and start ECU terminal D4-13 and ground
- Is there continuity?
Result
Result Yes No
Result: 2
No
See step 15
Result: 1
Yes
See step 11
- INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN ENTRY LOCK AND UNLOCK SWITCH AND CERTIFICATION ECU
- Disconnect the certification ECU and entry lock and unlock switch connector.
- Inspect for continuity between the following terminals (vehicle wiring harness).
- Entry lock and unlock switch (LF) terminal H8-2 and certification ECU terminal E33-2
- Entry lock and unlock switch (RF) terminal H9-2 and certification ECU terminal E33-1
- Is there continuity?
Result
Result Yes No
Result: 2
No
See step 14
Result: 1
Yes
See step 12
- VERIFY IF MALFUNCTION CAUSE WAS CORRECTED
Result: 1
Yes
TROUBLESHOOTING COMPLETED. (EXPLAIN THE CONTENTS OF THE SERVICING TO THE CUSTOMER.)
Result: 2
No
See step 13
- IF THE MALFUNCTION HAS NOT BEEN RESOLVED, REPEAT THE INSPECTION FROM STEP 1.
Result
Proceed to NEXT Result: 1
NEXT
See step 1
- REPAIR OR REPLACE THE WIRING HARNESS FOR AN OPEN CIRCUIT.
Result: 1
NEXT
See step 12
- REPAIR OR REPLACE THE WIRING HARNESS FOR AN OPEN CIRCUIT.
Result: 1
NEXT
See step 12
- REPAIR OR REPLACE THE WIRING HARNESS FOR AN OPEN CIRCUIT.
Result: 1
NEXT
See step 12
- REPAIR OR REPLACE THE WIRING HARNESS FOR AN OPEN CIRCUIT.
Result: 1
NEXT
See step 12
- INSPECT THE TRUNK LID OPENER SWITCH. IF THERE IS ANY MALFUNCTION, REPLACE IT.
Refer to INSPECTION
- If the trunk lid opener switch inspection is normal, inspect or repair the following:
- Luggage compartment door lock
Refer to INSPECTION
- Luggage compartment door lock
- After repair procedure, go to Step 12.
Result
Proceed to NEXT
Result: 1
NEXT
See step 12
- If the trunk lid opener switch inspection is normal, inspect or repair the following:
- REPAIR OR REPLACE THE WIRING HARNESS FOR AN OPEN CIRCUIT.
Result: 1
NEXT
See step 12