FixVault

On-Vehicle Inspection [08/2015 - 08/2017]: Procedure

  1. CHECK STOP LIGHT CONTROL RELAY 
    1. Remove the stop light control relays (BRK NO. 1 and BRK NO. 2) from the engine room relay block.
    2. Measure the resistance according to the value(s) in the table below.
      GTY480670Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard resistance

      FOR BRK NO. 1

      Tester Connection Condition Specified Condition
      3 - 4 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 When battery voltage is not applied to terminals 1 and 2 Below 1 Ω
      3 - 4 When battery voltage is applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω
      FOR BRK NO. 2

      Tester Connection Condition Specified Condition
      3 - 4 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      When battery voltage is applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.

    3. Install the stop light control relays (BRK NO. 1 and BRK NO. 2).