Inspection [08/2015 - ]: Procedure
- INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Switch Condition Specified Condition 5 (E) - 6 (P) Mode switch
(ECT PWR) onBelow 1 Ω Release mode switch
(ECT PWR) off10 kΩ or higher 5 (E) - 8 (2nd) Mode switch being pushed and held
(ECT 2nd)Below 1 Ω Mode switch not pushed
(ECT 2nd)10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(Integration Control and Panel Assembly)If the result is not as specified, replace the integration control and panel assembly.
- Measure the resistance according to the value(s) in the table below.