FixVault

Inspection [11/2015 - ]: Procedure

  1. INSPECT KNOCK CONTROL SENSOR 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Click Location & Routing(E1)

      Click Connector(E1)

      Tester Connection Condition Specified Condition
      E1-1 - E1-2 20°C (68°F) 120 to 280 kΩ

      If the result is not as specified, replace the knock control sensor.

      GTY694903Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Component without harness connected
      (Knock Control Sensor)