Vacuum Sensor Assembly (Manifold Absolute Pressure Sensor)

VACUUM SENSOR ASSEMBLY (MANIFOLD ABSOLUTE PRESSURE SENSOR)

Standard Voltage C2-3 (VC) - C2-1 (E2) Ignition switch ON 4.75 to 5.25 V
C2-2 (PIM) - C2-1 (E2) Ignition switch ON 3.0 to 5.25 V
Intake Manifold Pressure Vacuum of 67 kPa(abs) [503 mmHg(abs)] applied to vacuum sensor assembly (manifold absolute pressure sensor) 23 to 38 kPa(abs) [173 to 285 mm Hg(abs)]