Air Sensor Plate (Rest Position)

Upper edge of sensor plate must be below lower edge of sensor cone .070-080" (1.80-2.10 mm). See Fig 1 . If rest position is incorrect, raise sensor plate. Open or close wire clip to change position of sensor plate. DO NOT bend leaf spring.

Fig 1: Sensor Plate Rest Position
G121528Courtesy of VOLKSWAGEN UNITED STATES, INC.