FixVault

New Control Module, Installing

WARNING: This page is about a different variant/trim than selected.
WARNING:

Excessive shaking (e.g. dropping, impact) may destroy the control module. Control module must then no longer be used.

-- Slide all sealing rings -A- slightly over the valve dome.

Fig 1: Identifying Sealing Rings On New Control Module
GWWN45-10161Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

-- Place control module without canting it onto hydraulic unit.

Sealing rings are then brought into their end position.

-- Install the hydraulic unit and control module with the new inner Torx bolts diagonally according to the tightening specification.

NOTE:

A new control module may be installed a max. of two times to a used hydraulic unit, to ensure that the elastic gasket seals sufficiently.

A control module which was once in driving operation must not be installed a second time.