FixVault

Test Procedure

-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK 

Start diagnosis

-- Engine MUST be at room temperature.

-- Disconnect the EGR Motor -V338- /EGR Potentiometer -G212- connector.

-- Using a Multimeter, Check the EGR Motor -V338- /EGR Potentiometer -G212- electrical harness connector terminals 1 to 3 for voltage.

Specified value: about 5.0 V

-- Switch the ignition Off.

Continue test according to the following table:

Value Cause Test
If the specified value was not obtained: Open or shorted circuit Checking Wiring 
If the specified value was obtained: Check reference / Motor signal circuit Checking Wiring