FixVault

Test Procedure

-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK 

Start diagnosis

Make sure the engine is at room temperature.

-- Disconnect the Fuel Pump Relay -J17- electrical harness connector. Refer to applicable wiring diagram for proper relay location.

-- Switch the ignition ON.

-- Using a Multimeter, Check the Fuel Pump Relay -J17- electrical harness connector terminals 1 and 3 to Engine ground for voltage.

Specified value: Battery Voltage

-- Switch the ignition Off.

Continue test according to the following table:

Value Cause Test
If the specified value was not obtained: Open or shorted circuit Checking Wiring 
If the specified value was obtained: Check reference signal circuit Checking Activation