Checking Resistance

-- Measure the resistance of the Reducing Agent Line Heater (Heating Circuit 2) -Z104- connector terminals 1 and 2.

Specified value: 2.4 Ω (+/- 1Ω)

If the specification was Not obtained:

-- replace the Reducing Agent Line Heater (Heating Circuit 2) -Z104-.

-- Go to Final Procedures 

If the specified value was obtained:

-- Remove the Reducing Agent Heater Control Module -J891-. Refer to appropriate service information.

-- Using a Multimeter, Check the Reducing Agent Line Heater (Heating Circuit 2) -Z104- electrical harness connector to the Reducing Agent Heater Control Module -J891- electrical harness connector T5h for an open circuit.

Reducing Agent Line Heater (Heating Circuit 2) -Z104- electrical harness connector T2cq terminal Reducing Agent Heater Control Module -J891- electrical harness connector T5h terminal
2 1
1 Ground

Specified value: 1.5 Ω Max.

If the specification was Not obtained:

-- Check the wiring for a short circuit to ground, high resistance or an open circuit.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- If necessary, repair the wiring or connections and replace any open fuses.

-- Go to Final Procedures 

If the specified value was obtained:

Replace the Reducing Agent Heater Control Module -J891-.