Removal & Installation (MPC System)

  1. Disconnect battery. Disconnect electrical connector and vacuum hose from sensor. Remove attaching screws and remove pressure sensor.
  2. To install, reverse removal procedure. Make sure replacement part has same part number as removed part. Different part numbers reflect higher or lower pressure adjustments.