FixVault

Ignition Coil Resistance Test

  1. On all models, turn ignition off. Remove coil protective cap (if used). Remove coil wires and connect an ohmmeter across ignition coil primary terminals. See Fig 1. Take primary winding resistance reading.
  2. Set ohmmeter to x1000 scale. Connect ohmmeter leads to negative coil terminal and coil tower. Take secondary resistance reading. If either primary or secondary winding reading are not within specifications, replace coil.
Fig 1: Ignition Coil Resistance Tests
G29158
IGNITION COIL RESISTANCE SPECIFICATION

Application Primary Secondary
Turbo .80-2.0 7000-12,000
760 GLE 0.4-0.6 7000-12,000