Check ground connections
Connect ohmmeter between ground and terminals 5, 11 & 25. Resistance should be nearly 0 in all cases. Ground wires are connected to intake manifold.
Connect ohmmeter between ground and terminals 5, 11 & 25. Resistance should be nearly 0 in all cases. Ground wires are connected to intake manifold.