Neutral Start Switch Check (Response Code 2-2-3)

  1. Turn ignition off. Disconnect control unit connector. Using an ohmmeter, measure resistance between control unit terminal No. 2 and ground. See Figure . Ensure resistances are to specification as transmission shift lever is moved. See NEUTRAL START SWITCH RESISTANCE SPECIFICATIONS table.
  2. If resistances are not to specification, check switch, wiring and connections for an open or short circuit. If resistances are to specification, repeat SYSTEM COMPONENT CHECK. If no response code is generated during SYSTEM COMPONENT CHECK, go to CONTROL UNIT CHECK.
NEUTRAL START SWITCH RESISTANCE SPECIFICATIONS

Shift Lever Position Ohms
P (1) Zero
R Infinite
N (1) Zero
D Infinite
Other Positions Infinite
(1) This specification is approximate.