FixVault

Guard Alarm II Receiver

  1. Ensure all doors, hood and trunk are closed. Turn ignition on and off at least 5 times in 10 seconds. Indicator LED should start to flash. Leave ignition on. Once indicator LED starts flashing, first remote control must be programmed within 15 seconds.
  2. Press one button on one remote control. Programming is acknowledged by indicator LED lighting for about 2 seconds. Indicator LED will then start flashing for 10 seconds. Program other remote control within 10 seconds while indicator LED is flashing. Turn ignition off. Test remote controls.