New features of cooler

There is a new drainage pipe which guides the water away from the blower motor casing and the filter housing.

The evaporator surface has a new treatment and a polyurethane sheath to reduce corrosion and bad smells.

The compressor has a higher capacity and is installed directly on the auxiliary unit bracket.

The compressor is started in a new fashion to avoid opening the safety valve.

TEV supplies a more even temperature regulation by adapting the amount of coolant to any requirements.

The freeze protection temperature sensor measures the temperature of the air that goes by the evaporator.

Linear pressure sensor installed directly on wiper.

Blower delay as customer setting. The delay is activated when complaints of bad smells occur, to remove any condensation water from the evaporator.

Service valves on both low and high pressure side.

NOTE: Coolant may only be filled from the high pressure side to avoid liquid coolant getting into the compressor.