Final check
WARNING:
Ensure that nobody is in the car when the battery is being connected.
When all components have been installed:
- set the ignition to position II.
- connect the battery negative lead.
Check that:
- The SRS indicator lamp in the combined instrument panel is not lit constantly.
Fault-trace if the lamp is lit constantly.
NOTE:
Check that the SRS warning lamp is not defective by turning the key to position II. The SRS warning lamp should light and go out after approximately 3 seconds.