FixVault

Stop/Start Does Not Function Intermittently (TJ28794)

Publication date: 2015-06-15
Reference number: TJ28794

STOP/START DOES NOT FUNCTION INTERMITTENTLY

STOP/START DOES NOT FUNCTION INTERMITTENTLY

TECHNICAL SERVICE BULLETIN

Reference Number(s): TJ28794, Date of Issue:  June 15, 2015
VOLVO: 2015 All Models
SECTION: automatic, transmission (hydromechanical
GROUP: 4370

ATTACHMENT

-

VEHICLE TYPE

VEHICLE TYPE

Type Eng Eng Desc Sales Body Gear Steer Model Year Plant Chassis range Struc Week Range
1XX 26       D   2015-2015   0158359-0311476 201346-201410
1XX 40       D   2015-2015   0181044-0183343 201346-201410

CSC CUSTOMER SYMPTOM CODES

CSC CUSTOMER SYMPTOM CODES

Code Description
3M Driving/Automatic start/stop of engine/Does not work
3N Idling/Automatic start/stop of engine/Does not work

VST OPERATION NUMBER

VST OPERATION NUMBER

VST Operation Number Description
36004-2 Software control module downloading.

DTC DIAGNOSTIC TROUBLE CODES

DTC DIAGNOSTIC TROUBLE CODES

Control Module Code Fault Type
TCM 0B0D00 Intermittent
TCM P0B0D00 Intermittent

Rows beginning with * are modified

NOTE: If using a printed copy of this Technical Journal, first check for the latest online version.

TEXT

NOTE: THIS DOCUMENT SUPERSEDES THE PREVIOUS TECHNICAL JOURNAL 28794 DATED 2014-10-23. *Updated chassis limits. PLEASE UPDATE YOUR FILES.

DESCRIPTION

Customer might experience problem with stop/start function. The start/stop function will not activate when it is supposed to.

PRODUCT MODIFICATION

New TCM SW introduced from structure week 2014w11.

MATERIAL RETURN

Material for analysis can be requested in Vehicle Report. In other cases, follow normal routines.

VEHICLE REPORT

Yes, please submit a Vehicle Report if the service solution described in this TJ has no effect or if the vehicle is outside the chassis number range. Use concern area "Vehicle Report" and sub concern area "Support Needed", use function group 4371.

SERVICE

In case of customer complaints matching above symptoms, download a TCM Upgrade using VIDA.

SERVICE

In case of customer complaints matching above symptoms, update the TCM-SW with latest software in VIDA.