FixVault

Circuit/System Testing

  1. Ignition ON, observe the IAT sensor parameter with a scan tool while moving the IAT sensor connector and the ECM connector. The IAT sensor parameter should not fluctuate while moving the related harnesses and connectors.
    • If the IAT sensor value fluctuates while moving the harness, repair the appropriate harness/connector.
  2. Ignition OFF, disconnect the harness connector of the IAT sensor.
  3. Ignition ON, verify that the IAT sensor parameter is at -40°C (-40°F).
    • If greater than -40°C (-40°F), test the signal circuit of the IAT sensor for a short to ground. If the circuit/connections test normal, replace the ECM.
  4. Ignition ON, install a 3-amp fused jumper wire between the signal circuit and the low reference circuit of the IAT sensor. Verify the IAT sensor parameter is greater than 132°C (270°F).
    • If less than 132°C (270°F), test the signal circuit of the IAT sensor for a short to voltage or an open/high resistance. If the circuit/connections test normal, replace the ECM.
  5. If all circuits/connections test normal, test or replace the IAT sensor.