DTC Information: DTC Detecting Condition

Item Detecting Condition Possible cause
DTC Strategy
  • Signal check, low
  1. Poor connection
  2. Open or short to ground in power circuit
  3. Open or short to ground in signal circuit
  4. Faulty APS
Enable Condition
  • IG "ON"
Threshold value
  • APS2 voltage is lower than 0.312V
Diagnosis Time
  • Continuous
MIL On Condition
  • 1 driving cycle