FixVault

Control Circuit Inspection

  1. Ignition "OFF" & Disconnect HO2S (S2) connector.
  2. Ignition "ON"
  3. Measure voltage between Pin No. 4 (Control) terminal of HO2S (S2) harness connector and chassis ground.

    Specification  : Approx. 3.5V

  4. Is the measured voltage within specification?

    YES 

    NO