Diagnosis Procedure
- CHECK BCM POWER SUPPLY AND GROUND CIRCUIT
- Check BCM power supply and ground circuit. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair or replace the malfunctioning parts.
- CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH POWER SUPPLY AND GROUND CIRCUIT
- Check main power window and door lock/unlock switch power supply and ground circuit. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair or replace the malfunctioning parts.
- REPLACE MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH
-
- Replace main power window and door lock/unlock switch. Refer to Removal and Installation .
- Confirm the operation after replacement.
Is the result normal?
YES>>
Inspection End.
NO>>
Check intermittent incident. Refer to Intermittent Incident .
-