| Terminal No. (terminal symbol) | Item | Measuring condition | Standard |
|---|---|---|---|
| (R422) No. 1 (+B) ←→ Chassis ground | Voltage | Always | 10.5 - 16 V |
| (R422) No. 2 (SW-V) ←→ Chassis ground | Voltage | Always | 10.5 - 16 V |
| (R422) No. 3 (CLUTCH (GND)) ←→ Chassis ground | Resistance | Always | Less than 1 Ω |
| (R422) No. 4 (SOL (-)) ←→ Chassis ground | Voltage | During solenoid cancellation output | Less than 1 V |
| (R422) No. 5 (CLOSER (OPEN)) ←→ Chassis ground | Voltage | When power rear gate auto closer cancellation is in operation | 10.5 - 16 V |
| (R422) No. 6 (SOL (COMMON)) ←→ Chassis ground | Voltage | Always | 10.5 - 16 V |
| (R422) No. 7 (MOTOR (CLOSE)) ←→ Chassis ground | Voltage | When auto-close is in operation | 10.5 - 16 V |
| (R422) No. 8 (+POWER B) ←→ Chassis ground | Voltage | Always | 10.5 - 16 V |
| (R422) No. 9 (SEN-V) ←→ Chassis ground | Voltage | Always | 4 - 6 V |
| (R422) No. 10 (IGN) ←→ Chassis ground | Voltage | When ignition switch is ON | 10.5 - 16 V |
| (R422) No. 11 (CLUTCH (+)) ←→ Chassis ground | Voltage | When auto-close is in operation | 10.5 - 16 V |
| (R422) No. 12 (SOL (BUZZER)) ←→ Chassis ground | Resistance | When buzzer is OFF | Less than 1 Ω |
| (R422) No. 13 (CLOSER (CLOSE)) ←→ Chassis ground | Voltage | When power rear gate auto closer is in pull-in operation | 10.5 - 16 V |
| (R422) No. 14 (P-GND) ←→ Chassis ground | Resistance | Always | Less than 1 Ω |
| (R422) No. 15 (MOTOR (OPEN)) ←→ Chassis ground | Voltage | When auto-open is in operation | 10.5 - 16 V |
| (R422) No. 16 (SOL (+)) ←→ Chassis ground | Voltage | When solenoid lock is output | Less than 1 V |
| (R423) No. 1 (LIN) ←→ Chassis ground | - | Cannot be measured (LIN communication line) | - |
| (R423) No. 2 (HALF STOP SW) ←→ Chassis ground | Voltage | When memory height switch is ON | 10.5 - 16 V |
| (R423) No. 3 (SOL POS SW) ←→ Chassis ground | Voltage | Except for PRG at half-stop state | 4 - 6 V |
| (R423) No. 4 (SECTOR SW) ←→ Chassis ground | Voltage | When PRG is fully closed | Less than 1 V |
| (R423) No. 5 (-) ←→ Chassis ground | - | - | - |
| (R423) No. 6 (GATE SW) ←→ Chassis ground | Voltage | When PRG inner SW is ON | 10.5 - 16 V |
| (R423) No. 7 (-) ←→ Chassis ground | - | - | - |
| (R423) No. 8 (S-GND) ←→ Chassis ground | Resistance | Always | Less than 1 Ω |
| (R423) No. 9 (-) ←→ Chassis ground | - | - | - |
| (R423) No. 10 (SEN-A) ←→ Chassis ground | Voltage | When PRG is stopped | 4 - 6 V |
| (R423) No. 11 (T-SEN R) ←→ Chassis ground | Voltage | When sensor is ON | Less than 1 V |
| (R423) No. 12 (T SEN L) ←→ Chassis ground | Voltage | When sensor is ON | Less than 1 V |
| (R423) No. 13 (LATCH SW) ←→ Chassis ground | Voltage | When PRG is fully closed | 4 - 6 V |
| (R423) No. 14 (COURTESY SW) ←→ Chassis ground | Voltage | When PRG is fully closed | 4 - 6 V |
| (R423) No. 15 (HAZARD) ←→ Chassis ground | Voltage | When hazard switch is OFF | Less than 1 V |
| (R423) No. 16 (D SW) ←→ Chassis ground | Voltage | When driver's switch is ON | 10.5 - 16 V |
| (R423) No. 17 (-) ←→ Chassis ground | - | - | - |
| (R423) No. 18 (T-SEN GND) ←→ Chassis ground | Resistance | Always | Less than 1 Ω |
| (R423) No. 19 (SEN-GND) ←→ Chassis ground | Resistance | Always | Less than 1 Ω |
| (R423) No. 20 (SEN-B) ←→ Chassis ground | Voltage | When PRG is stopped | 4 - 6 V |