Primary Speed Sensor: Installation

CAUTION: If water or oil contacts the connector terminal of primary speed sensor, replace it with a new part.
  1. Install a new O-ring to the primary speed sensor.
    NOTE: Apply CVTF to the O-rings.
  2. Install the primary speed sensor.
    1. Install the primary speed sensor.

      Tightening torque: 

      7 N.m (0.7 kgf-m, 5.2 ft-lb)

    2. Connect the connector.
  3. Install the transmission body. Ref. to CONTINUOUSLY VARIABLE TRANSMISSION (TR580)>TRANSMISSION ASSEMBLY>INSTALLATION .
  4. Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>NOTE>BATTERY .