FixVault

Inspection Procedure

  1. Check ECU-B, DC/DC, GAUGE and DOOR fuse. 

    CHECK: 

    Check continuity of ECU-B, DC/DC, GAUGE and DOOR fuse.

    OK: 

    Continuity 

    NG: Replace the failed fuse. 

    OK: Go to next step 

  2. Check voltage between terminals B, BDR and E of body ECU connector. 

    PREPARATION: 

    1. Turn ignition switch OFF.
    2. Disconnect the Body ECU connector.

    CHECK: 

    Measure voltage between terminals B, BDR and E.

    OK: 

    Voltage: 10 - 14V 

    OK: Proceed to next circuit inspection shown on  PROBLEM SYMPTOMS TABLE  . 

    NG: Go to next step 

  3. Check wiring harness and connector between body ECU and body ground (See  HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE  ). 

    NG: Repair or replace wiring harness or connector. 

    OK: Check and repair wiring harness and connector between Body ECU and battery.