Read Configuration Procedure

WARNING: This page is about a different car, the 2007 Nissan Versa. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carries out CAN communication.
  1. With ignition switch OFF, connect CONSULT-II and CONSULT-II CONVERTER to data link connector and turn ignition switch ON.
    Fig 1: Connecting CONSULT-II And CONSULT-II Converter To Data Link Connector
    G04811544
  2. Touch "START (NISSAN BASED VHCL)".
    Fig 2: CONSULT-II Function Screen Display - START (NISSAN BASED VHCL)
    G04811545
  3. Touch "BCM" on "SELECT SYSTEM" screen. If "BCM" is not indicated, go to GENERAL INFORMATION section. Refer to CONSULT-II DATA LINK CONNECTOR (DLC) CIRCUIT  "  .
    Fig 3: CONSULT-II Function Screen Display - Select System
    G04811546
  4. Touch "BCM" on "SELECT TEST ITEM" screen.
    Fig 4: CONSULT-II Function Screen Display - SELECT TEST ITEM
    G04815645
  5. Touch "CONFIGURATION" on "SELECT DIAG MODE" screen.
    Fig 5: CONSULT-II Function Screen Display - SELECT DIAG MODE
    G04811547
  6. Touch "C11 (SPEC1)" and "OK" on "VEHICLE SELECT" screen. For canceling, touch "CANCEL" on "VEHICLE SELECT" screen.
    NOTE: Confirm vehicle model on IDENTIFICATION PLATE. Refer to MODEL VARIATION  "  .
    Fig 6: CONSULT-II Function Screen Display - SELECT DIAG MODE
    G04815647
  7. Touch "READ CONFIGURATION" on "SELECT CONFIG ITEM" screen.
    Fig 7: CONSULT-II Function Screen Display - SELECT CONFIG ITEM
    G04815648
  8. Configuration of current BCM is printed out automatically. A listing of manual setting items and auto setting items will be displayed. Auto setting items are preset and cannot be changed. Manual setting items can be set by using WRITE CONFIGURATION PROCEDURE. Refer to "WRITE CONFIGURATION PROCEDURE ".
    Fig 8: CONSULT-II Function Screen Display - WRITE CONFIGURATION PROCEDURE
    G04815649
  9. Touch "BACK" on "READ CONFIGURATION" screen.
    Fig 9: CONSULT-II Function Screen Display - READ CONFIGURATION
    G04815650